1300 025 780 Australia Wide sales@alphascientific.com.au
Select Page

AccuFit 9000 Professional Respirator Fit Tester

$0.00

The AccuFit 9000 from AccuTech is a latest generation professional respirator fit tester which uses just one mode for testing most full and half face mask respirators plus most disposable respirators. Since there’s no need to switch between modes for different respirators, you’ll save time and increase efficiency. The unit provides real-time quantitative results and is widely used across many industries throughout Australia and the world.

When operated in a standalone capacity, the AccuFIT 9000 requires no PC connectivity. All test results are conveniently stored on the unit’s memory stick that can be transferred to a computer when you’re ready, and it also means less equipment to transport and carry when conducting fit tests at multiple locations. When connected to a PC (via LAN, Wi-Fi, or USB), the AccuFIT 9000 will automatically download and store all test results to your computer. There’s even an extra USB port for direct connection to your printer or keyboard.

The Condensation Particulate Counter (CPC) used in the AccuFIT 9000 has been optimized to enhance counting efficiency. The good news – less chance of running out of particles and receiving an error message warning you that the ambient particle count is too low.

Description

The AccuFit 9000 from AccuTech is a latest generation professional respirator fit tester which uses just one mode for testing most full and half face mask respirators plus most disposable respirators. Since there’s no need to switch between modes for different respirators, you’ll save time and increase efficiency. The unit provides real-time quantitative results and is widely used across many industries throughout Australia and the world.

When operated in a standalone capacity, the AccuFIT 9000 requires no PC connectivity. All test results are conveniently stored on the unit’s memory stick that can be transferred to a computer when you’re ready, and it also means less equipment to transport and carry when conducting fit tests at multiple locations. When connected to a PC (via LAN, Wi-Fi, or USB), the AccuFIT 9000 will automatically download and store all test results to your computer. There’s even an extra USB port for direct connection to your printer or keyboard.

The Condensation Particulate Counter (CPC) used in the AccuFIT 9000 has been optimized to enhance counting efficiency. The good news – less chance of running out of particles and receiving an error message warning you that the ambient particle count is too low.

AccuFit 9000 Features

  • Fit tests ALL tight-fitting full & half face mask respirators
  • Easy to use 7” color touch screen control
  • Animations on screen for users to follow
  • Stand alone or PC operation
  • Control up to 4 units from a single computer with Independent start & stop times
  • Two modes of operation for particle size range
  • WiFi enabled
  • 6 Language Options
  • OSHA, ANSI, CSA, HSE Protocol compliant
  • Particle counting (CNC) technology
  • 3 USB ports + 1 Ethernet
  • Fully serviced, supported and calibrated in Australia
  • 3 Year Warranty

accufit 9000

What’s Included

  • AccuFit9000 Fit Tester
  • AC Adapter
  • Alcohol Fill Capsule, Cartridge & Storage Cap
  • UFTA-998 Universal Fit Testing Alcohol
  • UTFA-HSK 5′ Hose Sample Kit
  • Two HEPA Filters
  • Two Spare Alcohol Wicks
  • Custom Nanuk 930 Carrying Case
  • Accufit 9000 PC Application Software
  • Flash Memory Drive
  • USB & Ethernet Cable
  • Nylon Accessory & Gadget Wallet
  • Operation & Service Manual
  • 3 Year Warranty
  • Factory calibration certificate

The AccuFIT9000 quantitative respirator fit tester offers two set-up options for more convenient testing, regardless of location, all displayed on a 7” color touchscreen. NEW Software which allows you to readily migrate any data you have previously stored, even from other database formats, directly onto the software that supports your AccuFIT system.

Standalone – When operated in standalone, the AccuFIT9000 requires no PC connectivity. All test results are conveniently stored on the unit’s internal memory stick that can be transferred to a computer when you’re ready – and it also means less equipment to transport and carry when conducting fit tests at multiple locations!

PC Mode – When connected to a PC (via LAN, Wi-Fi, or USB), the AccuFIT9000 Pro will automatically download and store all test results to your computer. There’s even an extra USB port for direct connection to your printer or keyboard.

AccuFit 9000 & AccuFit 9000 Pro

If you are interested in also testing P2 filtering face pieces and some N95 masks, then you may wish to consider the AccuFit 9000 Pro model. In addition to all of the AccuFIT 9000 standard features, the PRO unit also has advanced Dual Mode technology to test ALL respirators, even Filtering face pieces with less efficient filtration performance such as FFP2 and some N95 types.

If your interested in respirator fit testing, you may also wish to check out our range of disposable mask and filter media testing systems which are widely used throughout Australasia and the world.

Specifications

  • Fit tests ALL tight-fitting full & half face mask respirators
  • Easy to use 7” color touch screen control
  • Animations on screen for users to follow
  • Stand alone or PC operation
  • Control up to 4 units from a single computer with Independent start & stop times
  • Two modes of operation for particle size range
  • WiFi enabled
  • 6 Language Options
  • OSHA, ANSI, CSA, HSE Protocol compliant
  • Particle counting (CNC) technology
  • 3 USB ports + 1 Ethernet
  • Fully serviced, supported and calibrated in Australia
  • 3 Year Warranty

Downloads

Product Brochure: AccuTec AccuFit 9000 Respirator Fit Tester – July 2025
Product Brochure: Iso Propyl Alcohol