Select Page

Calibration Services

Alpha Scientific offers a variety of popular in-house and on-site calibration services. Some of these are provided and or coordinated through our Melbourne head office, while other services are provided through our national calibration network partners with field service technicians being available in most states of Australia and in New Zealand. Some equipment is calibrated to a NATA (*)  standard to meet more stringent requirements, whereas other equipment is calibrated to the manufacturers factory standards and or other local and or international standards.

particle counter calibrations

Air Particle Counters

State-of-the-art, audit quality calibration services are available using factory trained engineers. Both onsite and in-house calibrations available to the global ISO 21501-4 standard on selected models. NATA / ISO 21501-4 /calibration available on other selected models & brands. (*)

liquid particle counters

Liquid Particle Counters

The most advanced liquid particle counter calibrations in Australasia using highly experienced GMP trained engineers at Beckman Coulter Australia. Calibrations are performed onsite across Australasia to the latest USP787, USP 788, USP789 global standards. These are not just validations / verification as some companies offer, but proper factory calibration and adjustments.

microbial air samplers calibration

Microbial Air Samplers

State-of-the-art calibration services for portable, fixed, tripod & robot based microbial air samplers of all flow rates from 0 to 200 LPM. Calibrations are performed to a NMI standard. Calibrations are undertaken by either Alpha Scientific or one of our national authorized calibration service providers using NATA calibrated reference equipment. Comprehensive documentation is provided.

Temperature sensors

Temperature Sensors

  • -35 deg C to + 650 deg C
  • +/- 0.2 deg C accuracy

Calibration of all sorts of temperature sensors and measurement instruments traceable to NMI standards using NATA ISO 17025 certified primary reference instrumentation. All calibrations are performed by highly trained staff and come with comprehensive documentation. (*)

humidity sensors

Humidity Sensors

  • 5 to 95% humidity range
  • +/- 0.8% accuracy

Calibration of all sorts of humidity sensors and measurement instruments traceable to NMI standards using NATA certified primary reference instrumentation. All calibrations are performed by highly trained staff and come with comprehensive documentation. (*)

differential pressure calibration

Differential Pressure

Calibration of many types of differential pressure sensors and measurement instruments traceable to NMI standards using NATA certified primary reference instrumentation. The option of NATA calibration is also available. All calibrations are performed by highly trained staff and come with comprehensive calibration documentation. (*)

gas & voc calibrations

Gases & VOCs

  • CO2 sensors & instruments
  • CO sensors & instruments
  • O2 sensors & instruments
  • SO2 sensors & instruments
  • NO sensors & instruments
  • Other gases

Calibrations are performed to an NMI standards using NATA certified reference instruments and gases. All calibrations are done by highly trained staff with professional documentation provided (*)

aerosol photometer calibration

Aerosol Photometers

Our state-of-the-art aerosol photometers for HEPA filter testing are manufactured by our ISO 17025 accredited global manufacturer and come supplied with an ILAC-MRA calibration certificate which is equivilent to NATA. Our aerosol photometers are currently re-calibrated in Australia to the latest JJF 1800 (2020) standard with a NATA calibration option coming soon. Various brands of aerosol photometers may also be calibrated (*)

palas spectrometer calibrations

Aerosol Spectrometers

  • Palas Fidas Frog
  • Palas AQ Guard Series
  • Palas Promo Series

Palas aerosol spectrometers including dust and air quality monitoring stations may be fully serviced and calibrated in Australia (in most cases) to Palas factory standards using precision mass flow meters, Palas Mono Dust calibration dust and other calibration measurement instruments.

Palas PMFT-1000 calibration

Mask & Filter Testers

  • Palas PMFT-1000
  • Palas PMFT-1000M
  • Palas PMFT-1000F (pending)

Palas PMFT-1000 series protective face mask and filter testing systems are maintained and calibrated in the field annually to Palas factory standards using Palas trained service technicians based in Melbourne, Australia. For more information or to book your calibration, please contact us.

air balancing hood calibration

Air Balancing Hoods

  • 25 to 800 l/s Range
  • 10 Point Calibration

Calibration of micro manometers and similar measurement instruments traceable to NMI standards using NATA certified primary reference instrumentation. All calibrations are performed by highly trained staff and come with comprehensive calibration documentation. (*)

Micro manometer calibration

Micro Manometers

Calibration of many types of micro manometers and similar measurement instruments traceable to NMI standards using NATA certified primary reference instrumentation. The option of NATA calibration is also available. All calibrations are performed by highly trained staff and come with comprehensive calibration documentation. (*)

vane anemometer calibration

Vane Anemometers

  • 0.30 to 45 m/s Range
  • 3, 5 or 10 Point Calibration

Calibration of many types of vane anemometers traceable to NMI standards using NATA ISO 17025 certified primary reference instrumentation. All calibrations are performed by highly trained staff and come with comprehensive calibration documentation. (*)

air velocity sensor calibration

Air Velocity Sensors

  • 0.30 to 45 m/s Range
  • 3, 5 or 10 Point Calibration

Calibration of many types of air velocity sensors traceable to NMI standards using NATA ISO 17025 certified primary reference instrumentation. All calibrations are performed by highly trained staff and come with comprehensive calibration documentation. (*)

mass flow meters

Mass Flow Meters

Calibration of many types of mass flow meters and similar measurement instruments traceable to NMI standards using NATA certified primary reference instrumentation. The option of NATA calibration is also available. All calibrations are performed by highly trained staff and come with comprehensive calibration documentation. (*)

hotwire anemometer calibration

Hotwire Anemometers

  • 0.30 to 45 m/s Range
  • 3, 5 or 10 Point Calibration

Calibration of many types of hotwire anemometers traceable to NMI standards using NATA ISO 17025 certified primary reference equipment. Calibrations are performed by highly trained staff and come with comprehensive calibration documentation. (*)

Toc analyzer calibration

Anatel TOC Analyzers

  • 21 CFR part 11 ALCOA calibrations
  • System suitability services to USP<643> and EP 2.2.44
  • TOC check used for “as found” and “as left” verification
  • TOC calibration adjustment for accurate performance, including calibration linearity
  • Verification of conductivity to USP <645>
  • IQ / OQ services fully compliant with USP <1058> requirements (*)

(*) Some of these services may be provided by a third party NATA laboratory affiliated with Alpha Scientific and or one of our national calibration network partners. Having calibration facilities in different states and territories offers great benefits to our customers when compared to customers having to ship equipment across the country to a single state based supplier.

Some organizations such as Beckman Coulter have major offices in Australia and have their own factory trained engineering staff located throughout Australia trained to undertake in-house and onsite calibration services for selected product lines. Nothing beats having the “actual manufacturer” of the equipment setup and trained in Australia to provide audit quality calibration services to the highest global standards.

In the world of scientific and environmental monitoring, accuracy and precision are paramount. To ensure the reliability of your data and the effectiveness of your operations, regular equipment calibration is an essential practice. The calibration services section below covers the numerous benefits of having your scientific and environmental monitoring equipment recalibrated annually.

Maintaining Accuracy

Precision is crucial in scientific research and environmental monitoring. Calibrating your equipment annually helps ensure that your instruments remain accurate. Over time, instruments can drift and lose their calibration, leading to inaccurate data and potentially costly errors. Regular calibration ensures that your equipment provides reliable and consistent measurements, giving you confidence in your results.

Compliance with Standards

Many industries and regulatory bodies require adherence to specific calibration standards. Regular calibration helps you stay in compliance with these standards, avoiding potential legal and regulatory issues. It also demonstrates your commitment to producing reliable and accurate data, which can enhance your reputation in the industry.

Quality Assurance

Calibrated equipment contributes to better quality control in your operations. By maintaining the accuracy of your instruments, you reduce the risk of producing faulty products or making incorrect decisions based on flawed data. This, in turn, can save you time and money by preventing costly errors.

Extended Equipment Lifespan

Regular calibration can extend the lifespan of your equipment. Calibration identifies and addresses minor issues early on, preventing them from becoming major problems that could lead to equipment failure. This proactive approach can save you the expense of frequent equipment replacements.

Improved Safety

In some applications, the incorrect measurements produced by uncalibrated equipment can pose safety risks. For example, in environmental monitoring, inaccurate data might lead to incorrect environmental assessments, potentially endangering public health. Regular calibration helps mitigate these risks and ensures a safer working environment.

Enhanced Data Quality

Accurate and precise data are essential for making informed decisions. Calibrated equipment provides the high-quality data needed for research, analysis, and decision-making, improving the overall effectiveness of your scientific and environmental monitoring efforts. calibration services

Cost Savings

While regular calibration involves an initial investment, it can save you money in the long run. Preventing errors and equipment failures reduces downtime, repair costs, and the need for frequent replacements. Additionally, accurate data can lead to more efficient resource allocation and cost-effective problem-solving. calibration services

Customer Confidence

When customers or clients rely on your data and services, demonstrating a commitment to calibration instills confidence in your brand. It signifies your dedication to providing accurate and dependable results, fostering trust and long-term relationships with your customers. calibration services

Regular equipment calibration is not just a routine maintenance task; it’s a critical practice that directly impacts the accuracy, quality, and safety of your scientific and environmental monitoring efforts. By investing in annual calibration, you not only ensure the reliability of your data but also reap numerous long-term benefits, including compliance, cost savings, and enhanced customer trust.

Make calibration an integral part of your equipment maintenance strategy to enjoy these advantages and maintain a competitive edge in your industry. Alpha Scientific also offers a range of calibration systems and instruments which may be purchased and used for the calibration of specific types of equipment.Calibration services