1300 025 780 Australia Wide sales@alphascientific.com.au
Select Page

Beckman Coulter PAT700 Advanced TOC Analyzers

$0.00

When pharmaceutical manufacturers demand uncompromising confidence in their water quality, they choose instrumentation that delivers accuracy, compliance, reliability and operational simplicity. The Beckman Coulter PAT700 Total Organic Carbon (TOC) Analyzer has been engineered specifically for pharmaceutical water systems, providing continuous online monitoring of Purified Water (PW), Water for Injection (WFI) and Clean-in-Place (CIP) applications.

Designed around the needs of GMP manufacturing, the PAT700 combines exceptional analytical performance with intelligent automation to reduce operator intervention, minimize downtime and simplify regulatory compliance. For pharmaceutical manufacturers, this means greater process confidence, improved operational efficiency and lower lifetime ownership costs. Ideal for Purified Water (PW) and Water for Injection (WFI) systems, and for Clean-In-Place processes, the PAT700 helps meet pharmacopeial standards including USP<643>, USP<645>, and EP 2.2.44.

Category:

Description

When pharmaceutical manufacturers demand uncompromising confidence in their water quality, they choose instrumentation that delivers accuracy, compliance, reliability and operational simplicity. The Beckman Coulter PAT700 Total Organic Carbon (TOC) Analyzer has been engineered specifically for pharmaceutical water systems, providing continuous online monitoring of Purified Water (PW), Water for Injection (WFI) and Clean-in-Place (CIP) applications.

Designed around the needs of GMP manufacturing, the PAT700 combines exceptional analytical performance with intelligent automation to reduce operator intervention, minimize downtime and simplify regulatory compliance. For pharmaceutical manufacturers, this means greater process confidence, improved operational efficiency and lower lifetime ownership costs. Ideal for Purified Water (PW) and Water for Injection (WFI) systems, and for Clean-In-Place processes, the PAT700 helps meet critical pharmacopeial standards including USP<643>, USP<645>, and EP 2.2.44.

Key Features

  • 3-in-1 Measurement – Measures TOC, Uncompensated Conductivity, and Temperature from a single analyzer
  • Pharmacopeial Compliance – Can be fully validated to meet USP <643> and EP2.2.44 requirements for TOC, and USP <645> for Conductivity
  • Extended Service Intervals – Requires calibration and servicing only once every 12 months
  • Automated Sample Capture – Automatically collects a water sample when a TOC excursion is detected for root-cause analysis
  • Pre-Loaded SOPs with Visual Guidance – Intuitive, step-by-step Standard Operating Procedures with on-screen pictures and prompts

Key Benefits

  • Ensure Regulatory Compliance – Maintain confidence in meeting global pharmacopeial requirements with validated performance
  • Simplify Operations and Training – Built-in SOPs reduce operator errors and accelerate onboarding of new users
  • Minimize Downtime and Maintenance Costs – Long calibration and service intervals lower the total cost of ownership
  • Rapid Troubleshooting – Immediate sample capture helps diagnose and resolve TOC anomalies quickly and effectively
  • Compact, Integrated Solution – Combines multiple measurements in one unit, saving space and simplifying system integration

Why the PAT700 Leads the Industry

Unlike many TOC analyzers that have been adapted from general industrial applications, the PAT700 was developed specifically for pharmaceutical water systems. Every feature has been designed to help manufacturers comply with global pharmacopeial requirements while maintaining maximum uptime and process reliability. It supports validation to USP <643>, USP <645> and European Pharmacopoeia 2.2.44 requirements for TOC and conductivity monitoring.

Complete Oxidation for Maximum Measurement Confidence

Accurate TOC measurement begins with complete oxidation of organic contaminants. The PAT700 fully oxidizes every sample before analysis, delivering highly accurate, repeatable TOC measurements across an exceptionally wide operating range. Dynamic endpoint detection further enhances measurement precision by ensuring every sample is analyzed completely before results are reported.

Three Critical Measurements in One Instrument

The PAT700 simultaneously measures:

  • Total Organic Carbon (TOC)
  • Uncompensated Conductivity
  • Sample Temperature

This integrated approach reduces instrumentation requirements while providing a complete picture of pharmaceutical water quality from a single analyzer.

PAT 700 Exceptional Sensitivity

With a detection limit down to just 0.5 ppb carbon and outstanding repeatability, the PAT700 easily exceeds the requirements of modern pharmaceutical water monitoring. Whether monitoring high-purity Water for Injection or Purified Water distribution loops, users benefit from rapid detection of even the smallest process deviations

Reduce Downtime & Costs

Every hour of analyzer downtime creates risk for pharmaceutical manufacturing. The PAT700 has been engineered to maximize instrument availability through intelligent design features including:

  • 12-month calibration intervals
  • 12-month service intervals
  • Automatic UV lamp switching
  • Minimal routine maintenance
  • Intuitive touchscreen interface
  • Guided maintenance procedures with built-in SOPs

The result is less planned maintenance, fewer service interruptions and significantly lower total cost of ownership compared with traditional online TOC analyzers.

Faster Root Cause Investigation

Most TOC analyzers simply alarm when an excursion occurs. The PAT700 goes much further. Its automated excursion capture function immediately collects a representative water sample whenever elevated TOC is detected. This enables laboratory investigation of the actual event, helping quality teams identify contamination sources more quickly and implement corrective actions with confidence.

PAT700 – Built for GMP Compliance

Regulatory compliance isn’t an afterthought, t’s at the heart of the PAT700 design. The analyzer supports pharmaceutical manufacturers with features including:

  • Validation support
  • Automated system suitability testing
  • Secure electronic records
  • Audit-friendly operation
  • Pharmacopeial compliant TOC testing
  • Conductivity testing within a single platform

These capabilities simplify qualification while helping manufacturers maintain confidence during regulatory inspections.

PAT700 – User Friendly by Design

Sophisticated analytical performance shouldn’t require specialist operators. The PAT700 features a modern color touchscreen interface with pre-loaded Standard Operating Procedures, visual prompts and guided maintenance workflows. New operators become productive quickly while experienced users benefit from streamlined daily operation.

  • Less training
  • Fewer operator errors.
  • More confidence

Why Pharmaceutical Manufacturers Choose the PAT700

  • Designed specifically for pharmaceutical water systems
  • Simultaneous TOC, conductivity and temperature measurement
  • Detection down to 0.5 ppb carbon
  • Complete sample oxidation for highly accurate TOC results
  • Supports USP <643>, USP <645> and EP 2.2.44 compliance
  • Automatic TOC excursion sample capture
  • 12-month calibration and maintenance intervals
  • Built-in SOPs with guided maintenance
  • Low lifetime operating costs
  • Proven reliability for GMP manufacturing environments

Protect Your Most Critical Utility

Water is one of the most critical raw materials in pharmaceutical manufacturing. Continuous, reliable monitoring is essential for product quality, regulatory compliance and operational efficiency. The Beckman Coulter PAT700 delivers the analytical performance, reliability and intelligent automation that modern pharmaceutical manufacturers demand, making it one of the most capable online TOC analyzers available for pharmaceutical water monitoring today.

Whether you’re designing a new pharmaceutical water system or upgrading an existing installation, the PAT700 provides the confidence to keep your process running at its best.

Specifications

Specification Beckman Coulter PAT700 TOC Analyzer
Measurement Technology Differential conductivity with complete UV oxidation
TOC Measurement Range 0.5–2,000 ppb Carbon
TOC Resolution 0.1 ppb
TOC Accuracy ±3 ppb or ±5% of reading (whichever is greater)
TOC Repeatability ±0.3 ppb or ±1% (whichever is greater)
TOC Detection Limit 0.5 ppb
Conductivity Range 0.05–150 μS/cm (@ 25°C)
Conductivity Accuracy ±2% over full range (uncompensated)
Resistivity Range 0.2–18 MΩ·cm (@ 25°C)
Temperature Measurement Accuracy ±0.5°C
Sample Water Temperature 1–95°C
Ambient Operating Temperature 10–40°C
Sample Flow Rate 60–300 mL/min
Sample Pressure 69–690 kPa (10–100 psi)
UV Lamps Dual UV lamp system with automatic main/standby switching
Display Full-color touchscreen
Analog Outputs 3 × configurable 4–20 mA outputs
Digital Outputs 4 × configurable digital outputs
Digital Inputs 2 × digital inputs
Communications Ethernet
Standards System Onboard Automated Standards Introduction System (OASIS)
Dimensions (W × D × H) 597 × 229 × 254 mm (23.5 × 9 × 10 in.)
Weight 13.6 kg (30 lb)
Maximum Altitude 4,000 m
Enclosure Rating IP56 (conduit version) / IP46 (quick-connect version)
Power Requirements 100/230 VAC ±10%, 50/60 Hz, 65 W
Compliance USP <643>, USP <645>, EP 2.2.44, 21 CFR Part 11
Calibration 3-point TOC calibration; conductivity calibration to USP <645>
Recommended Service Interval 12 months
Suitable Applications Purified Water, Water for Injection, Clean-in-Place, pharmaceutical water systems

 

Downloads

Product Brochure: Beckman Coulter PAT700 Brochure
Application Note: Beckman Coulter PAT700 TOC Analyzer CIP Application Note
Technical Note: Beckman Coulter PAT700 TOC Excursion Mode Tech Note
Other Resources: Click HERE