The Hach QBD1200 is a state-of-the-art TOC analyzer designed to make testing easier, reproducible and highly accurate. The Hach QBD1200 promises the highest performance while dramatically reducing the cost of ownership by using one reagent for the test and requiring only one annual service call rather than frequent maintenance. The unit is fully compliant with the latest USP, EP, JP, IP, KP, ICH global pharmacopoeia regulations. The unit features a large 10.4 inch color screen, its fully 21 CFR-11 compliant and its packed full of other regulatory and data security features.

Category:

Description

The Hach QBD1200 is a state-of-the-art TOC analyzer designed to make testing easier, reproducible and highly accurate. The Hach QBD1200 promises the highest performance while dramatically reducing the cost of ownership by using one reagent for the test and requiring only one annual service call rather than frequent maintenance. The unit is fully compliant with the latest USP, EP, JP, IP, KP, ICH global pharmacopoeia regulations. The unit features a large 10.4-inch color screen, its fully 21 CFR-11 compliant and its packed full of other regulatory and data security features.

Key Features

  • 0 to 100ppm measurement range
  • <2% or 3ppb precision, whichever is greater
  • +/- 3% accuracy
  • Low cost of ownership. Say goodbye to frequent maintenance, reduce service calls from once a month to once a year
  • Low reagent cost
  • Fast automatic calibration takes only 2 hours

Reliable Measurement Data for TOC

  • Stop throwing away your first sample. The Hach QbD1200 plus has virtually eliminated sample-to-sample carryover
  • The QbD1200 plus has excellent reproducibility and good stability of measurement results
  • Dynamic endpoint detection technology can ensure

– Full oxidation of the organic matter
– Sufficient removal of the inorganic carbon

  • No extra modules to remove the inorganic carbon
  • Digital NDIR detector can automatically correct the background and drift, ensuring long-term stability
  • It can be very effectively used in purified water, injection water and cleaning verification, with a range up to 100 ppm

Hach QBD1200 Plus

Simplify Your Validation & Analysis

  • The Hach QbD1200 plus can be measuring within one hour after unpacking
  • No external PC is required, so there is no additional computer system to verify compliance of 21 CFR 11
  • Display the user interface through the large 10.4-inch color touchscreen
  • Automated calibrations, system suitability testing and report generation
  • The intuitive user interface means you’ll never have to refer to a complicated manual
  • Automatic adjustment range / automatic dilution function means you never have to know the sample concentration in advance
  • Highest performance by using one reagent for all tests

Ensure Regulatory Compliance

  • Fully compliant with major global pharmacopoeia regulations: USP, JP, EP, IP, KP, ICH
  • Simplified IQ / OQ / PQ certification procedures comply with ICH guidelines
  • Simple automated routines can be used in the following areas:
    – USP / EP SST bulk water
    – USP SST sterile water
    – JP SDBS validation
    – KHP calibration in accordance with Japanese standards

Data Security

  • Designed for use in 21 CFR Part 11 lab environments
  • The paperless function is simple and convenient, data can be exported in a network shared directory managed by Windows security policy management
  • Data and reports are sent to the same location for centralized record keeping
  • The integrated hard drive encrypts all data and has sufficient storage space for the entire measurement life
  • Reports can be created at the touch of a button

Design Concept

  • Each time the self-health check is performed after the Hach QbD1200 plus is powered on, and it can also be adjusted as needed
  • There are multiple types of sensors placed at 10 different monitoring points, which can continuously perform pressure, liquid flow, gas flow, temperature inspection and NDIR detection
  • Easily ensure that all subsystems are working normally to ensure reliable measurements

Specifications

Specification Details
Product Name Hach QBD1200+ Laboratory TOC Analyzer
Instrument Type Laboratory Total Organic Carbon (TOC) Analyzer
Product Number 9890310 / 9890800
Measurement Technology UV/Persulfate Wet Oxidation
Oxidation Method UV Lamp + Persulfate
Detector Type Digital NDIR Detector
Measurement Range 0.4 ppb – 100 ppm TOC
Precision 3% or 3 ppb, whichever is greater
Sample-to-Sample Carryover <0.2%
Overload Recovery 1 measurement
Particle Size Tolerance Up to 100 µm
Calibration Interval 1 year
Calibration Time 90 minutes
Calibration Method Automated 18-point calibration using KHP standards
Calibration Standard KHP (Potassium Hydrogen Phthalate)
Calibration Configuration 6 concentration points repeated 3 times
Startup Time Ready within minutes
Daily Verification Background test only
Inorganic Carbon Removal No external IC removal module required
Sample Handling Automatic range adjustment and dilution
Autosampler Compatibility Yes
Multi-Station Capability Compatible with 3 stations
Sample Homogenisation Optional autosampler available
Carrier Gas CO₂-free air, O₂, or N₂
Display Type 10.4-inch high-resolution color touchscreen
User Interface Integrated touchscreen interface
Data Integrity Support 21 CFR Part 11 compliant
External PC Requirement None
Data Export Formats PDF, CSV
Report Generation Automated
Connectivity Secure network reporting support
Self-Diagnostics Multi-sensor self-health monitoring
Compliance Standards USP, EP, JP, IP, CP, KP
Regulatory Compliance FDA 21 CFR Part 11
Additional Standards ISO 8245, DIN EN 1483, USEPA 5310C
Power Supply 100 – 240 VAC
Frequency 47 – 63 Hz
Dimensions (H × W × D) 410 × 320 × 507 mm
Weight 14 kg
Warranty 12 months