1300 025 780 Australia Wide sales@alphascientific.com.au
Select Page

Pegasor PPC Diesel Exhaust Particulate Monitor

$0.00

The Pegasor PPC diesel exhaust particulate monitor is an amazing new generation portable instrument capable of being used for many industry applications. It’s optimized for diesel and petrol engine exhaust particulate measurements and allows compliance testing in accordance with various global standards. This unit may be used for stack particulate analysis and various other applications and is it is uniquely capable of measuring particulates from as low as 10nm up to 1,000nm (1um) in size.

Developed in Finland, the Pegasor PPC uses ExtDC technology to eliminate soot clogging. The straight-through-design keeps the sensor clean for extended operating periods. It’s absolutely feature packed, with the latest communications options, Bluetooth wireless connectivity and much more.

Description

The Pegasor PPC diesel exhaust particulate monitor is an amazing new generation portable instrument capable of being used for many industry applications. It’s optimized for diesel and petrol engine exhaust particulate measurements and allows compliance testing in accordance with various global standards. This unit may be used for stack particulate analysis and various other applications and is it is uniquely capable of measuring particulates from as low as 10nm up to 1,000nm (1um) in size.

Developed in Finland, the Pegasor PPC uses ExtDC technology to eliminate soot clogging. The straight-through-design keeps the sensor clean for extended operating periods. It’s absolutely feature packed, with the latest communications options, Bluetooth wireless connectivity and much more.

The Pegasor PPC covers a wide particle size range, requires no consumables (unlike many similar systems), requires no flammable and costly operating liquids, requires no dilution, is extremely low maintenance and requires calibration typically every 2 years versus every 12 months or sooner with many similar instruments. And most importantly, this technology is fully portable and affordable for the average customer to purchase.

Pegasor PPC

What it Measures

  • Particle number as particles per cubic cm from 10nm to 1,000nm (1um)
  • Particle number in accordance with European NPTI regulations (23nm to 1um)
  • Lung deposited surface area (LDSA) from 10nm to 1,000nm (1um)
  • Particle mass displayed in ug/m3 from 10nm to 300nm (0.3um)
  • Particle size (median particle size measurement) from 10nm to 300nm (0.3um)

Pegasor PPC Features

  • 10nm to 1,000nm particle size range
  • Capable of measuring those potentially deadly ultra-fine particles below 100nm unlike photometer based devices
  • Real-time particle detection based on the electrical detection of particles
  • Ideal for PTI-PN testing (periodic technical inspection) of diesel particulate filters fitted to vehicles
  • 30 to 100,000,000 particles cm/3 wide particle concentration range
  • Fast 0.2 second response time
  • 1 to 10 Hz ultra-fast sampling rate
  • Low air consumption < 8 LPM @ 300mbar
  • Incorporates the latest Pegasor PPS-G2 sensor for particle detection
  • Internal heaters and volatile particle remover for VOC removal
  • Integrated air supply for sensor operation
  • Extensive self-diagnostics
  • RS232, USB, Bluetooth & Ethernet communications
  • Software provided for remote control and access
  • The ability to mount the probe and remotely sample from the device thus not exposing the operator to diesel particulates
  • Comes with a heated sampling line for connection to a sampling point
  • 2m heated sampling line (90°C, adjustable) included with 4m length optional)
  • No compressed air required
  • Insensitive to vibrations
  • Patented clog free technology
  • No soot build-up
  • Hot sheath air protected sensor which is very resistant to contamination
  • No consumables needed
  • No flammable and costly operating liquids needed as with some competitive devices
  • No dilution required as is the case with some competitive systems
  • Maintenance interval up to 2 years

Approvals & Certifications

  • NMI approved for nPTI measurements
  • PTB approved for nPTI measurements
  • METAS approved for nPTI measurements
  • Fully complies with the German PTI requirements
  • Fully complies with the Swiss PTI requirements
  • Fully complies with the Netherlands PTI requirements

The Pegasor PPC is commonly used in professional engine workshops throughout the world and when used alongside other engine testing equipment, it can provide additional data including particle concentration per kwh. The Pegasor PPC is one instrument in a wide range of diesel particulate monitoring instruments available from Alpha Scientific. In addition, Alpha Scientific offers a wide range of ultra-fine and nano-particle measurement equipment for many industry applications.

Specifications

  • 10nm to 1,000nm particle size range
  • Capable of measuring those potentially deadly ultra-fine particles below 100nm unlike photometer based devices
  • Real-time particle detection based on the electrical detection of particles
  • Ideal for PTI-PN testing (periodic technical inspection) of diesel particulate filters fitted to vehicles
  • 30 to 100,000,000 particles cm/3 wide particle concentration range
  • Fast 0.2 second response time
  • 1 to 10 Hz ultra-fast sampling rate
  • Low air consumption < 8 LPM @ 300mbar
  • Incorporates the latest Pegasor PPS-G2 sensor for particle detection
  • Internal heaters and volatile particle remover for VOC removal
  • Integrated air supply for sensor operation
  • Extensive self-diagnostics
  • RS232, USB, Bluetooth & Ethernet communications
  • Software provided for remote control and access
  • The ability to mount the probe and remotely sample from the device thus not exposing the operator to diesel particulates
  • Comes with a heated sampling line for connection to a sampling point
  • 2m heated sampling line (90°C, adjustable) included with 4m length optional)
  • No compressed air required
  • Insensitive to vibrations
  • Patented clog free technology
  • No soot build-up
  • Hot sheath air protected sensor which is very resistant to contamination
  • No consumables needed
  • No flammable and costly operating liquids needed as with some competitive devices
  • No dilution required as is the case with some competitive systems
  • Maintenance interval up to 2 years

Downloads

Brochure: Pegasor PPC Brochure Jan 2025

Videos